Concepts in Chemical Equilibria |
---|
Acid dissociation constant |
Binding constant |
Binding selectivity |
Buffer solution |
Chemical equilibrium |
Chemical stability |
Dissociation constant |
Distribution coefficient |
Distribution ratio |
Dynamic equilibrium |
Equilibrium chemistry |
Equilibrium constant |
Equilibrium unfolding |
Equilibrium stage |
Liquid-liquid extraction |
Phase diagram |
Predominance diagram |
Phase rule |
Reaction quotient |
Solubility equilibrium |
Stability constants of complexes |
Thermodynamic equilibrium |
Vapor-liquid equilibrium |
edit |
In chemistry and the pharmaceutical sciences, a partition- (P) or distribution coefficient (D) is the ratio of concentrations of a compound in the two phases of a mixture of two immiscible solvents at equilibrium.[1] Hence these coefficients are a measure of differential solubility of the compound between these two solvents. The phrase "Partition Coefficient" is now considered obsolete by IUPAC, and the appropriate alternative ("partition constant", "partition ratio" or "distribution ratio") should be used as appropriate.[2]
Normally one of the solvents chosen is water while the second is hydrophobic such as octanol.[3] Hence both the partition and distribution coefficient are measures of how hydrophilic ("water loving") or hydrophobic ("water fearing") a chemical substance is. A partition coefficient can also be used when one or both solvents is a solid though. In medical practice, partition coefficients are useful for example in estimating distribution of drugs within the body. Hydrophobic drugs with high partition coefficients are preferentially distributed to hydrophobic compartments such as lipid bilayers of cells while hydrophilic drugs (low partition coefficients) preferentially are found in hydrophilic compartments such as blood serum.
Contents |
The partition coefficient is a ratio of concentrations of un-ionized compound between the two solutions. To measure the partition coefficient of ionizable solutes, the pH of the aqueous phase is adjusted such that the predominant form of the compound is un-ionized. The logarithm of the ratio of the concentrations of the un-ionized solute in the solvents is called log P:
The distribution coefficient is the ratio of the sum of the concentrations of all forms of the compound (ionized plus un-ionized) in each of the two phases. For measurements of distribution coefficient, the pH of the aqueous phase is buffered to a specific value such that the pH is not significantly perturbed by the introduction of the compound. The logarithm of the ratio of the sum of concentrations of the solute's various forms in one solvent, to the sum of the concentrations of its forms in the other solvent is called Log D:
In addition, log D is pH dependent, hence the one must specify the pH at which the log D was measured. Of particular interest is the log D at pH = 7.4 (the physiological pH of blood serum). For un-ionizable compounds, log P = log D at any pH.
A drug's distribution coefficient strongly affects how easily the drug can reach its intended target in the body, how strong an effect it will have once it reaches it target, and how long it will remain in the body in an active form.
In the context of pharmacokinetics (what the body does to a drug), the distribution coefficient has a strong influence on ADME properties (Absorption, Distribution, Metabolism, and Excretion) of the drug. Hence the hydrophobicity of a compound (as measured by its distribution coefficient) is a major determinant of how drug-like it is. More specifically, in order for a drug to be orally absorbed, it normally must first pass through lipid bilayers in the intestinal epithelium (a process known as transcellular transport). For efficient transport, the drug must be hydrophobic enough to partition into the lipid bilayer, but not so hydrophobic, that once it is in the bilayer, it will not partition out again.[4] Likewise, hydrophobicity plays a major role in determining where drugs are distributed within the body after adsorption and as a consequence in how rapidly they are metabolized and excreted.
In the context of pharmacodynamics (what a drug does to the body), the hydrophobic effect is the major driving force for the binding of drugs to their receptor targets.[5][6] On the other hand, hydrophobic drugs tend to be more toxic because they in general are retained longer, have a wider distribution within the body (e.g., intracellular), are somewhat less selective in their binding to proteins, and finally are often extensively metabolized. In some cases the metabolites may be chemically reactive. Hence it is advisable to make the drug as hydrophilic as possible while it still retains adequate binding affinity to the therapeutic protein target.[7] Therefore the ideal distribution coefficient for a drug is usually intermediate (not too hydrophobic nor too hydrophilic).
Many other industries take into account distribution coefficients for example in the formulation of make-up, topical ointments, dyes, hair colors and many other consumer products.
Hydrophobic insecticides and herbicides tend to be more active. Hydrophobic agrochemicals in general have longer half lives and therefore display increased risk of adverse environmental impact.
In metallurgy, the partition coefficient is an important factor in determining how different impurities are distributed between molten and solidified metal. It is a critical parameter for purification using zone melting, and determines how effective an impurity can be removed using directional solidification, described by the Scheil equation.
The hydrophobicity of a compound can give scientists an indication of how easily a compound might be taken up in groundwater to pollute waterways, and its toxicity to animals and aquatic life.[8] Distribution coefficients may be measured or predicted for compounds currently causing problems or with foresight to gauge the structural modifications necessary to make a compound environmentally more friendly in the research phase.
In the field of hydrogeology, the octanol water partition coefficient, or Kow, is used to predict and model the migration of dissolved hydrophobic organic compounds in soil and groundwater.
The classical and most reliable method of log P determination is the shake-flask method, which consists of dissolving some of the solute in question in a volume of octanol and water, then measuring the concentration of the solute in each solvent. The most common method of measuring the distribution of the solute is by UV/VIS spectroscopy. There are a number of pros and cons to this method:
Pros:
Cons:
As an alternative to UV/VIS spectroscopy other methods can be used to measure the distribution, one of the best is to use a carrier free radiotracer. In this method (which is well suited for the study of the extraction of metals) a known amount of a radioactive material is added to one of the phases. The two phases are then brought into contact and mixed until equilibrium has been reached. Then the two phases are separated before the radioactivity in each phase is measured. Using an energy dispersive detector (such as a high purity germanium detector) allows the use of several different radioactive metals at once, whereas the simpler gamma ray detectors only allow one radioactive element to be used in the sample.
If the volume of both of the phases are the same then the math is very simple.
For a hypothetical solute (S)
D or P = radioactivity of the organic phase / radioactivity of the aqueous phase
D or P = [Sorganic]/[Saqueous]
In such an experiment using a carrier free radioisotope the solvent loading is very small, hence the results are different from those which are obtained when the concentration of the solute is very high. A disadvantage of the carrier free radioisotope experiment is that the solute can absorb on the surfaces of the glass (or plastic) equipment or at the interface between the two phases. To guard against this the mass balance should be calculated.
It should be the case that
radioactivity of the organic phase + radioactivity of the aqueous phase = initial radioactivity of the phase bearing the radiotracer
For nonradioactive metals, it is possible in some cases to use ICP-MS or ICP-AES. Sadly ICP methods often suffer from many interferences which do not apply to gamma spectroscopy so hence the use of radio-tracers (counted by gamma ray spectroscopy) is often more straightforward.
A faster method of log P determination makes use of high-performance liquid chromatography. The log P of a solute can be determined by correlating its retention time with similar compounds with known log P values.[9]
Pros:
Cons:
In the recent past some experiments using polarised liquid interfaces have been used to examine the thermodynamics and kinetics of the transfer of charged species from one phase to another. Two main methods exist.
QSPR (Quantitative Structure-Property Relationship) algorithms calculate a log P in several different ways:
The given values[22] are sorted by the partition coefficient. Acetamide is hydrophilic and 2,2',4,4',5-Pentachlorobiphenyl is lipophilic.
Component | log POW | T (°C) |
---|---|---|
Acetamide[23] | -1.16 | 25 |
Methanol[24] | -0.82 | 19 |
Formic acid[25] | -0.41 | 25 |
Diethyl ether[24] | 0.83 | 20 |
p-Dichlorobenzene[26] | 3.37 | 25 |
Hexamethylbenzene[26] | 4.61 | 25 |
2,2',4,4',5-Pentachlorobiphenyl[27] | 6.41 | Ambient |
Values for other compounds may be found in Sangster Research Laboratories' database.[28]
Log P is not an accurate determinant of lipophilicity for ionizable compounds because it only correctly describes the partition coefficient of neutral (uncharged) molecules . Taking the example of drug discovery we see how the limitations of log P can affect research. Since the majority of drugs (approximately 80%) are ionizable, log P is not an appropriate predictor of a compound's behaviour in the changing pH environments of the body. The distribution coefficient (Log D) is the correct descriptor for ionizable systems . Alternatively, use may be made of the apparent partition coefficient which is defined as follows: (true partition coefficient) x (fraction of the drug which is unionised). Clearly, if the drug is 100% unionised then Papparent = Ptrue .
There are many logP calculators or predictors available both commercially and for free.
|